APPA 30 Series
Advanced Instrument Technology Made Easy
The State-of-the-Art Clamp-On Measuring Instruments
Distrubuted by:
APPA TECHNOLOGY CORPORATION
9F, 119-1 Pao-Zong Rd., Shintien, Taipei, 231, TAIWAN
Tel: +886-2-29178820 Fax: +886-2-29170848
E-mail: [email protected]· http://www.appatech.com
ISO 9001 CERTIFIED
Specifictions subject to change without notice.
Copyright © 2005 APPA Tech., Corp. All rights reserved
GENERAL:
Display: LCD digital readout 4000 count 4000 count 2000 count 4000 count 4000 count 4000 count 4000 count 4000 count
Measuring Rate: Times per second 4 T/sec 4 T/sec 2.5T/sec 4 T/sec 2 T/sec 2 T/sec 2 T/sec 2 T/sec
Overrange indication: "OL" "OL" "OL" "OL" "OL" "OL" " OL" " OL"
Low Battery Indicaton: Red LED Red LED Red LED
Auto Power Off: Approx 30 minutes • • • • 10 minutes
Operating Temperature: 0°C~50°C, 80% R.H. • • 0°C~45°C, 80%RH • •
Storage Temperature: -20°C~60°C • •
Temperature Coefficient: 0.2x(spec. Acc’y)/°C,<18°C or >28°C • • •
Shock Proof: 4 feet drops • • • •
Safety: IEC 61010 and designed to meet UL 3111 specifications CAT. II 600V CAT. II 600V CAT. III 600V CAT. III 1000V CAT. II 600V CAT. II 600V CAT. III 600V, CAT. II 1000V CAT. III 600V, CAT. II 1000V CAT. III 600V CAT. II 600V CAT. III 1000V CAT. III 600V, CAT. II 1000V
Maximum Conductor Size: ø29mm ø34mm ø22mm ø51mm ø40mm ø29mm ø34mm ø51mm ø35mm ø22mm ø51mm ø51mm
Maximum Jaw Opening: 30mm 38mm 25mm 53mm 42mm 30mm 37mm 53mm 45mm 25mm 53mm 53mm
Maximum Busbar Size: 20x40mm 24x60mm 24x60mm 40x15mm 24x60mm 24x60mm
Power Requirement: Single 9V battery (NEDA 1604,IEC 6F22) • • • Alkaline AAA SIZE1.5Vx2
Battery Life: In hours (Alkaline battery) 45 66 66 200 200 200 200 150 50 40 40
Size: WxLxD in mm 72x148x36, w/o cable 60x203x27,w/o cable 65.5x185x40,w/o cable 90x232x32,w/o cable 88x215x36 77x194x36 76x200x41 105x268x42 82x208x41 66x192x27 106x240x40 100x265x42
Weight: In grams 250 380 320 420 320 250 360 420 360 205 420 420
Included with Instrument: Safety test leads • • • •
Battery(ZnC) User supplied Installed Installed Installed Installed Installed Installed Installed Installed Installed (Installed)Alkaline
Coiled cable output plugs Installed Installed Installed Installed
User’s manual • •
Carrying Case • •
APPA 30 SERIES CLAMP INSTRUMENTS
SPECIFICATIONS: (All at 23°C±5°C, 80% R.H.)
APPA 31 APPA 32 APPA 30T APPA 39T APPA33/33R APPA 35N/35R APPA 33II/33RII APPA 39AC/39AR APPA 36II/36RII APPA 30 /30R APPA 39/39R APPA 39MR
AC VOLTAGE: Ranges: 400V,600V 400V,600V 600V 400V, 400V , 600V
Resolution: 0.1V 0.1V 0.1V 0.1V 0.1mV 0.1mV 0.1V
Accuracy: ±(1.2%+5d),40Hz~500Hz ±(1.2%+5d),40Hz~500Hz ±(1.2%+3d),40Hz~500Hz ±(1.2%+5d),40Hz~500Hz ±(1.5%+5d),40Hz~500Hz ±(1.5%+5d),40Hz~500Hz ±(1.2%+5d),50Hz~500Hz
Input Impedance: 10M//<100pF • • • • • • •
Overload Protection: 600Vrms • 850V rms
Conversion Type: Average sensing RMS indicating 33 • 33R True RMS 35N • 35R True RMS 33II • 33RII True RMS 39AC • 39AR True RMS 36II • 36RII True RMS 30 • 30R True RMS 39 • 39R True RMS True RMS
DC VOLTAGE: Ranges: 400V, 1000V 400mV~600V 400mV~600V 400V, 1000V
Resolution: 0.1V 0.1mV 0.1mV 0.1V
Accuracy: ±(0.7%+5d) ±(0.7%+2d) ±(0.5%+2d) ±(0.7%+2d)
Input Resistance: 10M 11M
Overload Protection: 600V rms 1000V DC • 1000V DC
AC CURRENT: Ranges: 400A 100A,600A 40A,300A 100A.1000A 400A,600A 400A 200A,600A
400A,1000A(39AR)/1200A(39AC) 400A,600A 40A,300A 400A,1000A 400A, 1000A
Resolution: 1mV/A 10mV/A,1mV/ A 10mV/A,1mV/ A 10mV/A,1mV/ A 0.1A 0.1A 0.1A 0.1A 100mA 10mA 0.1A 0.1A
Accuracy: 50~60Hz 45Hz~400Hz 40Hz~400Hz 40Hz~400Hz 50Hz~60Hz 50Hz~60Hz 50Hz~60Hz 50Hz~60Hz 50Hz~60Hz 50Hz~60Hz 40Hz~400Hz 40Hz~400Hz
±(1.9%+0.5A),0A~350A ±(2%+2A),0A~ 100A ±(1.0%+0.1A),0A~ 40A ±(1.9%+2A), 0A~100A ±(1.9%+5d),0A~400A ±(1.9%+5d) ±(1.9%+5d),200A ±(1.9%+8d), 0A~40A ±(1.9%+7d),0A~40A ±(1.0%+5d),0A~4A ±(1.9%+8d),0A~40A ±(1.5%+5d), 0A~600A
±(3.2%+1A),350A~400A ±(2%+2A),100A~400A ±(1.0%+1A),40A~200A ±(1.9%7A),100A~400A ±(2.9%+5d),400A~600A ±(1.5%+5d),0A~400A ±(1.9%+5d), 40A~400A ±(1.9%+5d),40A~400A ±(1.0%+3d),4A~200A ±(1.9%+7d),40A~400A 40Hz~200Hz
±(3%+2A),400A~600A ±(1.9%+2A),200A~300A ±(2.9%+5A),400A~1000A ±(2.5%+5d),400A~600A
±(2.9%+5d), 400A~1000A(39A) ±(1.9%+10d),400A~600A ±(3%+3d),200A~300A ±(2.9%r+5d),400A~1000A ±(2.5%r+5d), 600A~1000A
±(2.9%+5d), 400A~1200A(39A) 61Hz~400Hz 40HZ~1KHZ
±(2.5%+7d),0A~40A ±(2.0%+7d),0A~4A
±(2.5%+5d),40A~400A ±(1.5%+5d),4A~200A
±(2.5%+10d),400A~600A ±(5%+5d),200A~300A
Conversion Type: Average sensing RMS indicating 33 • 33R True RMS 35N • 35R True RMS 33II • 33RII True RMS 39AC • 39AR True RMS 36II • 36RII True RMS 30 • 30R True RMS 39 • 39R True RMS True RMS
FREQUENCY COUNT: Ranges: 20Hz~10KHz 20Hz~10KHz
Accuracy: ±(0.5%+3d) ±(0.5%+3d)
DC CURRENT: Ranges: 100A,600A 40A,300A 100A,1000A 400A,600A 40A,300A 400A,1000A 400A,1000A
Resolution: 10mV/A,1mV/A 10mV/A,1mV/A 10mV/A,1mV/A 100mA 10mA 0.1A 0.1A
Accuracy: ±(2%+2A),0A~100A ±(1.0%+0.1A),0A~40A ±(2.9%+2A),0A~100A ±(1.5%+10d),0A~40A ±(1.0%+2d),0A~200A ±(2.9%+8d),0A~100A ±(1.0%+3d), 0A~600A
±(2%+2A),100A~400A ±(1.0%+1A),40A~200A ±1.9%+7A),100A~400A ±(1.5%+7d),40A~400A ±(2.0%+2d),200A~300A ±(1.9%+5d),100A~400A ±(1.9%+5d), 600A~1000A
±(3%+2A),400A~600A ±(1.9%+2A),200A~300A ±(2.9%+5A),400A~600A ±(1.9%+10d),400A~600A ±(2.9%+5d),400A~1000A
RESISTANCE: Ranges: 4K, 40K 4K , 40K 2000 4K , 40K 400~40M 400~40M 4K, 40K
Resolution: 1 1 1 1 0.1 0.1 1
Accuracy: ±(1.2%+6d),0~400 ±(1.2%+6d),0~400
±(2% rdg + 9d) ±(1.9% rdg + 8d) ±(1.5% rdg + 2d) ±(2% + 9d) ±(.0.9%+3d),400~40K ±(.0.9%+3d),400~40K ±(1.0%g+2d)
±(1.2%+3d),40K~4M ±(1.2%+3d),40K~4M
±(2.5%+5d),4M~40M ±(2.5%+5d),4M~40M
Overload Protection: 600V rms 600V rms 600V rms 600V rms 600Vrms 600Vrms 600V rms
CONTINUITY TEST: Threshold: < 200 approximate • <100 approximate <50 approximate <100 approximate <50 approximate <50 approximate <100 approximate
Indicator: 2KHz tone buzzer • • •
Load Impedance: AC and DC 100K min 100K min
Position Error: ±1%rdg ±1%rdg ±1%rdg ±1%rdg ±1%rdg ±1%rdg ±1%rdg
Output Voltage: AC/DC,10mV/A in 100A, 1mV/A in 1000A AC 1mV per 1A
AC/DC, 10mV/A in 100A,1mV/A in 600AAC/DC, 10mV/A in 40A,1mV/A in 300A
Type of Sensing : Current transformer sensing • •
Hall effect sensing for AC and DC • • • •
Vista de pagina 0
1 2

Indice de contenidos

Pagina 1 - APPA 30 Series

APPA 30 Series Advanced Instrument Technology Made EasyThe State-of-the-Art Clamp-On Measuring InstrumentsDistrubuted by:APPA TECHNOLOGY CORPORATION

Pagina 2 - AC/DC CURRENT TRANSDUCER

AC CURRENT/VOLTAGE/RESISTANCE CLAMP METERAPPA 39ACAPPA 39AR (True-RMS reading)4000 count digital displayAC 1200A in specificationAC 1000A in specifica

Comentarios a estos manuales

Sin comentarios